Cones (Section 6F.59) |
Bent Manufacturing Company, Inc.
17311 Nichols Street
Huntington Beach, CA 92647-5721
(888) 842-0600 |
42" T-Top Stackable Channelizer Cone |
| Retroreflectorization of cones that are more than 36 inches in height shall be provided by horizontal, circumferential, alternating orange and white retroreflective stripes that are 4 to 6 inches wide. Each cone shall have a minimum of two orange and two white stripes with the top stripe being orange. Any nonretroreflective spaces between the orange and white stripes shall not exceed 3 inches in width. |
Tubular Markers (Section 6F.60) |
Manufacturer |
Product Name |
Bent Manufacturing Company, Inc. 17311 Nichols Street Huntington Beach, CA 92647-5721 (888) 842-0600 |
Masterflex Surface Mount Channelizer Post |
Masterflex Post EX-Series
|
Three D Traffic Works, Inc.
430 N. Varney St.
Burbank, CA 91502
(877) 843-9757 |
TD5200 Series Boomerang
Surface Mount Reboundable Delineators
|
| Shall be a min. 28" in height, orange in color with white/silver retroreflective sheeting and meet all MUTCD requirements for day and nighttime use. |
Pexco
3110 70th Avenue East Tacoma, WA 98424 (800) 822-7528 |
Flexi-Guide FG 300 Model UR |
Flexi-Guide FG 300 Model EFX
|
| Shall be a min. 28" in height, orange in color with white/silver retroreflective sheeting and meet all MUTCD requirements for day and nighttime use. |
Flexstake, Inc.
2150 Andrea Lane
Fort Meyers, FL 33912
(800) 348-9839 |
e-base
Surface Mount Flexible Delineator |
Shall be a min. 28" in height, orange in color with white/silver retroreflective sheeting and meet all MUTCD requirements for day and nighttime use.
When a noncylindrical tubular marker is used, it shall be attached to the pavement in a manner such that the width facing road users meets the minimum requirements. (2003 MUTCD Section 6F.60)
|
New Direction Manufacturing, Inc.
830 Hydrangea Drive
North Fort Myers, FL 33903
(239) 464-6591 |
360 Surface Mount Delineator |
| Shall be a min. 28" in height, orange in color with white/silver retroreflective sheeting and meet all MUTCD requirements for day and nighttime use. |
Vertical Panels (Section 6F.61) |
Bent Manufacturing Company, Inc.
17311 Nichols Street
Huntington Beach, CA 92647-5721
(888) 842-0600 |
Ultra Panel
stackable vertical panel and drop over base |
| Markings for vertical panels shall be alternating orange and white retroreflective stripes, sloping downward at an angle of 45 degrees in the direction vehicular traffic is to pass. Vertical panels used on freeways, expressways, and other high-speed roadways shall have a minimum of 270 square inches retroreflective area facing vehicular traffic. |
Drums (Section 6F.62) |
Manufacturer |
Product Name |
Bent Manufacturing Company, Inc.
17311 Nichols Street
Huntington Beach, CA 92647-5721
(888) 842-0600 |
Superdome Drum |
Plasticade Products
7700 North Austin Ave.
Skokie, Illinois 60077
(800) 323-4250 |
Rhino Channelizer Drum[1] |
[1] 44" tall. Available in high or low density polyethylene D-shape bottom and base design reduces rolling after impact.
|
Type I, II, or III Barricades (Section 6F.63) |
Manufacturer |
Product Name |
Bent Manufacturing Company, Inc. 17311 Nichols Street Huntington Beach, CA 92647-5721 (888) 842-0600 |
Type I & II Waffle Board Plastic Panel Barricades |
Type III Barricades |
Universal Plastic Barricade, Type I and II
|
Plasticade Products
7700 North Austin Ave.
Skokie, Illinois 60077
(800) 323-4250 |
Plasticade Type I & II |
Sentinel Type III |
Pexco
3110 70th Avenue East
Tacoma, WA 98424
(800) 822-7528
|
T3B Barricade
Plastic Type III Barricade |
MaineDOT Standard Specification 652.2 requires three- 8 inch wide rails, 8 feet in length, with the top rail a minimum of 5 feet from the roadway for a Type III barricade. Otherwise, barricades shall meet all requirements of the latest edition of the MUTCD. |
Temporary Traffic Barriers as Channelizing Devices (Section 6F.65) |
Manufacturer |
Product Name |
Off the Wall Products LLC
180 South 300 West Suite 326
Salt Lake City, UT 84101
(888) 363-7740
|
Multi-Barrier Model MB350
(42"H x72"L x24"W) |
| Follow MUTCD guidelines for use and selection of color, etc. Units must be interconnected and firmly fixed to the ground. Units need not be ballasted for this application |
Longitudinal Channelizing Barricades (Section 6F.66) |
Manufacturer |
Product Name |
Plasticade Products
7700 North Austin Ave.
Skokie, Illinois 60077
(800) 323-4250
|
Verticalcade
|
| Stackable with or without bases. Drop over bases come in 20 lbs and 30 lbs |
Off the Wall Products LLC
180 South 300 West Suite 326
Salt Lake City, UT 84101
(888) 363-7740
|
MB42x45 LCB
(42"Hx45"Lx23.5"W)
|
| Ballast with 8 gallons of water per unit when used as a longitudinal channelizing device (LCB). Use as an LCB is limited to summer months only. Do not use anti-freeze. Liquid must be collected and disposed of properly. May be used to channelize pedestrians. |
The Yodock Wall Company, Inc.
PO Box 354
Bloomsburg, PA 17815
(570) 380-2856 |
Yodock 2001SL
Slimline Channelizer
(18"Hx72"Lx12"W) |
| Ballast with 35 gallons of water per unit when used as a longitudinal channelizing device (LCB). Use as an LCB is limited to summer months only. Do not use anti-freeze. Liquid must be collected and disposed of properly. May be used to channelize pedestrians. |
Detectable Edging for Pedestrians (Section 6F.68)
|
Manufacturer |
Product Name |
Off the Wall Products LLC
180 South 300 West Suite 326
Salt Lake City, UT 84101
(888) 363-7740 |
Multi-Barrier Model MB350
(42"H x72"L x24"W) |
| Follow MUTCD guidelines for use and selection of color, etc. Units must be interconnected and firmly fixed to the ground. Units need not be ballasted for this application |
Temporary Traffic Barriers (Section 6F.81) |
Manufacturer |
Product Name |
Off the Wall Products LLC
180 South 300 West Suite 326
Salt Lake City, UT 84101
(888) 363-7740 |
Multi-Barrier Model MB350
(42"H x72"L x24"W) |
| Limited to use in summer months only. Do not use anti-freeze. Liquid must be collected and disposed of properly. The MB350 steel bar kit must be used when units are configured for use as a barrier. To achieve NCHRP 350 TL-3 compliance, 33 interconnected barriers (198.5 ft.) must be used and each unit must be full ballasted. |